Cabin Coolers
Cabin Coolers
0.00TL
Ex Tax: 0.00TL
- Stok: Stokta Var
- Marka: Friterm
- Model: Kabin Soğutucuları
New Water Drainage System
Drainage water is drained quickly and easily thanks to the inclined water drain pan.
Hinged, Retractable Side Cover and Drain Pan
Thanks to its hinged structure, the side covers and the drain pan can be opened and closed easily, allowing easy intervention.
Exploded Outlet Chambers in Different Directions for Collector / Distributor Outputs
Developed for collector / distributor outlets, blasted outlets in different directions and outlet connections can be made optionally from the lower or upper part.
Advanced Pipe and Fin Structure for High Thermal Efficiency
Internally grooved special pipes are used in order to improve the heat transfer in the Two-Phase flow of the Refrigerant. High performance is provided with improved heat transfer thanks to the special wing structure on the air side.
FEATURES AND APPLICATIONS
• FEWR model ceiling type room coolers can be applied to commercial cold and frozen storage rooms with small and medium cooling capacity and include a wide capacity range from 0.5 kW to 24.8 kW. Standard (S) and low (L) sound level products are available.
• Friterm FEWR series are ceiling-mounted evaporators that blow in one direction, try to push, as standard.
• Suitable for working with R404A, R507, R134A, ... refrigerants.
• Capacities are given for R404A.
Battery Features
• Straight pipe arrangement that reduces defrost time and defrost energy consumption,
• 4-7 mm lamella spacing,
• Special grooved copper pipe for evaporators, aluminum lamella,
• Copper pipe inlet-outlet connections,
• Refrigerant distributor
• Optimum circuitry,
• Test Pressure: 34 bar (PED 2014/68/EU)
• Maximum operating pressure: 22 bar
CASING
• Casing from AlMg3 material,
• Electrostatic powder coated (RAL 9016) cassette; smooth, permanent, corrosion-resistant decorative structure,
• Hinged easy-to-open side doors and bottom pan.
Drain Pan
• Hinged pan in all product models
FANS
• High efficiency axial type EBM, ELCO or equivalent fans with diameters of 200- 250- 300- 350 mm are used in FEWR ceiling type room coolers with Freon.
• Motor protection class IP 44- IP 54 and IP 65; The insulation class is B and F.
• The lowest operating temperature is -25˚C, depending on the fan diameter.
• Special fans should be used in operating conditions below -25˚C.
• Fans work in the direction of discharge as standard.
• 200/ 250/ 300/ 350 mm fans as standard 230V 1~50 Hz,
• Thermistor connections must be made in fans with thermistors used for motor protection.
• Friterm has the right to use different brands of fans. Depending on this situation, there may be partial differences in fan information.
SOUND LEVELS
• Sound pressure levels of the products are given in the catalog in accordance with EN 13487 standard.
• While calculating the sound levels, the sound power levels (LwA) given by the fan manufacturers are used.
• Consult an expert in cases where sound levels are critical.
ACCESSORIES
• Electric heater in the battery
• Wall hanging apparatus
• Drain heater
OPTIONS AND VERSIONS
• Air defrost
• Hot gas defrost (battery and pan)
• Coated lamellas
• Coated battery
• AISI 304 or AISI 316 stainless steel cassette
• Different lamella spacing options
• EC fan
• Stainless steel tube (AISI 304, AISI 316)
• Expansion valve assembly